Schneider LC1D32M7 15KW/400V 20HP/480V, 3 Poles 32A Screw terminal

Price:

₹ 2,712.15

Indian Pricelist
Mechtrace by CS Bakery Solutions
PAF 3016 30X34X16 mm
PAF 3016 30X34X16 mm
₹ 315.00
₹ 350.00 (10% OFF)
CS aerotherm Lead Screw for LMAP-2400 Moulder
CS aerotherm Lead Screw for LMAP-2400 Moulder
₹ 1,404.00
₹ 1,560.00 (10% OFF)

Schneider LC1D32M7 15KW/400V 20HP/480V, 3 Poles 32A Screw terminal

https://www.mechtrace.com/web/image/product.template/156/image_1920?unique=c5693cc
(1 review)

Schneider LC1D32M7 15KW/400V 20HP/480V, 3 Poles 32A Screw terminal

₹ 2,712.15 2712.15 INR ₹ 3,013.50

₹ 3,013.50



    TeSys D contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3/3e (15kW@400V). It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

    SPECIFICATIONS:

    Range of productTeSys Deca
    Product or component typeContactor
    Device short nameLC1D
    Contactor applicationResistive load
    Motor control
    Utilisation categoryAC-4
    AC-1
    AC-3
    AC-3e
    Poles description3P
    [Ue] rated operational voltagePower circuit: <= 690 V AC 25...400 Hz
    Power circuit: <= 300 V DC
    [Ie] rated operational current32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    [Uc] control circuit voltage220 V AC 50/60 Hz
    Complementary
    Motor power kW7.5 kW at 220...230 V AC 50/60 Hz (AC-3)
    15 kW at 380...400 V AC 50/60 Hz (AC-3)
    15 kW at 415...440 V AC 50/60 Hz (AC-3)
    18.5 kW at 500 V AC 50/60 Hz (AC-3)
    18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
    7.5 kW at 400 V AC 50/60 Hz (AC-4)
    7.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
    15 kW at 380...400 V AC 50/60 Hz (AC-3e)
    15 kW at 415...440 V AC 50/60 Hz (AC-3e)
    18.5 kW at 500 V AC 50/60 Hz (AC-3e)
    18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
    Motor power hp2 hp at 115 V AC 50/60 Hz for 1 phase motors
    5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
    10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
    20 hp at 460/480 V AC 50/60 Hz for 3 phases motors
    30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
    Compatibility codeLC1D
    Pole contact composition3 NO
    Contact compatibilityM2
    Protective coverWith
    [Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
    50 A (at 60 °C) for power circuit
    Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
    250 A DC for signalling circuit conforming to IEC 60947-5-1
    550 A at 440 V for power circuit conforming to IEC 60947
    Rated breaking capacity550 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current260 A 40 °C - 10 s for power circuit
    430 A 40 °C - 1 s for power circuit
    60 A 40 °C - 10 min for power circuit
    138 A 40 °C - 1 min for power circuit
    100 A - 1 s for signalling circuit
    120 A - 500 ms for signalling circuit
    140 A - 100 ms for signalling circuit
    Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
    63 A gG at <= 690 V coordination type 1 for power circuit
    63 A gG at <= 690 V coordination type 2 for power circuit
    Average impedance2 mOhm - Ith 50 A 50 Hz for power circuit
    Power dissipation per pole2 W AC-3
    5 W AC-1
    2 W AC-3e
    [Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1
    Power circuit: 600 V CSA certified
    Power circuit: 600 V UL certified
    Signalling circuit: 690 V conforming to IEC 60947-1
    Signalling circuit: 600 V CSA certified
    Signalling circuit: 600 V UL certified
    Overvoltage categoryIII
    Pollution degree3
    [Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
    Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    Mechanical durability15 Mcycles
    Electrical durability1.65 Mcycles 32 A AC-3 at Ue <= 440 V
    1.4 Mcycles 50 A AC-1 at Ue <= 440 V
    1.65 Mcycles 32 A AC-3e at Ue <= 440 V
    Control circuit typeAC at 50/60 Hz standard
    Coil technologyWithout built-in suppressor module
    Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
    0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
    0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
    1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
    Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C)
    70 VA 50 Hz cos phi 0.75 (at 20 °C)
    Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
    7 VA 50 Hz cos phi 0.3 (at 20 °C)
    Heat dissipation2…3 W at 50/60 Hz
    Operating time12...22 ms closing
    4...19 ms opening
    Maximum operating rate3600 cyc/h 60 °C
    Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
    Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
    Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 1 1…10 mm² - cable stiffness: flexible with cable end
    Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible with cable end
    Power circuit: screw clamp terminals 1 1.5…10 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: solid without cable end
    Tightening torqueControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    Auxiliary contact composition1 NO + 1 NC
    Auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
    type mirror contact 1 NC conforming to IEC 60947-4-1
    Signalling circuit frequency25...400 Hz
    Minimum switching voltage17 V for signalling circuit
    Minimum switching current5 mA for signalling circuit
    Insulation resistance> 10 MOhm for signalling circuit
    Non-overlap time1.5 ms on de-energisation between NC and NO contact
    1.5 ms on energisation between NC and NO contact
    Mounting supportPlate
    Rail
    Environment
    StandardsCSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    IEC 60335-1
    Product certificationsDNV
    RINA
    LROS (Lloyds register of shipping)
    CCC
    CSA
    GL
    GOST
    BV
    UL
    UKCA
    IP degree of protectionIP20 front face conforming to IEC 60529
    Protective treatmentTH conforming to IEC 60068-2-30
    Climatic withstandConforming to IACS E10 exposure to damp heat
    conforming to IEC 60947-1 Annex Q category D exposure to damp heat
    Permissible ambient air temperature around the device-40…60 °C
    60…70 °C with derating
    Operating altitude0...3000 m
    Fire resistance850 °C conforming to IEC 60695-2-1
    Flame retardanceV1 conforming to UL 94
    Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz)
    Vibrations contactor closed (4 Gn, 5...300 Hz)
    Shocks contactor closed (15 Gn for 11 ms)
    Shocks contactor open (8 Gn for 11 ms)
    Height85 mm
    Width45 mm
    Depth92 mm
    Net weight0.375 kg
    Packing Units
    Unit Type of Package 1Db
    Number of Units in Package 11
    Package 1 Height5 cm
    Package 1 Width9.2 cm
    Package 1 Length11.2 cm
    Package 1 Weight410 g
    Unit Type of Package 2S02
    Number of Units in Package 220
    Package 2 Height15 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight8.502 kg
    Unit Type of Package 3P06
    Number of Units in Package 3160
    Package 3 Height45 cm
    Package 3 Width60 cm
    Package 3 Length80 cm
    Package 3 Weight76.016 kg